Opened 4 years ago

Closed 4 years ago

#1053 closed (fixed)

Netgear WGR614L bricks with BS builds.

Reported by: redhawk0 Owned by: Eko
Keywords: Cc:

Description

Eko generated some fixes around 11600 that allows the Netgear 614L/v8 unit to be updated directly from the generic.bin builds. (I use mini) The Eko builds will allow this upgrade...but the BS builds will not. Was there a commit forgotten for those changes?

I get a blinking Power LED and the Yellow "Check" light comes on. If I hook up serial and manually start the tftp daemon, I can recover with the same BS svn build...but it requires the .chk file....once reloaded the unit works as normal. I just can't update it using the .bin file like I can with the Eko builds.

redhawk

Attachments (1)

WGR614L-serial.txt (7.5 KB) - added by redhawk0 4 years ago.
Serial output data when failing.

Download all attachments as: .zip

Change History (6)

comment:1 Changed 4 years ago by Eko

  • Owner changed from somebody to Eko
  • Status changed from new to assigned

I will try to check and to reproduce here...

comment:2 Changed 4 years ago by Eko

From what svn build did you try to upgrade?

comment:3 Changed 4 years ago by redhawk0

It doesn't seem to matter what svn I am coming from. This last time was from 11995 to 12006....but it has happened with BS to BS builds...or from Eko to BS builds. So far I have not been able to get any BS .bin build to update correctly...only his .chk files.

I'll try to get some serial data for you tomorrow.

Changed 4 years ago by redhawk0

Serial output data when failing.

comment:4 Changed 4 years ago by redhawk0

OK...I attached the serial data. This occurred from 11995 (eko) to the 12006 (BS) build. Incorrect checksum seems to be the culprit.

With a static IP address and tftp, I can load the .chk (12006) directly to recover.

redhawk

comment:5 Changed 4 years ago by Eko

  • Resolution set to fixed
  • Status changed from assigned to closed

fixed in r12026